Back to Top

1
Hi, Guest!
  • Nova 600 Series Portable Multi Gas Analyzer For Ambient
Nova 600 Series Portable Multi Gas Analyzer For Ambient

Nova 600 Series Portable Multi Gas Analyzer For Ambient

Update Terakhir 28 / 11 / 2021
Minimal Pembelian 0 Unit

Harga

CALL
Bagikan
DESKRIPSI PRODUK

Detail Nova 600 Series Portable Multi Gas Analyzer For Ambient

The Nova 600 Series Portable Multi-gas Ambient Air analyzers are convenient and accurate portable instruments for monitoring up to six gases simultaneously from ambient air samples. A built in sample pump draws in the sample gas where it is analyzed by up to six separate detectors. These detector outputs are then amplified and displayed on separate, easy-to-read digital meters. The electrochemical sensors for O2, CO, SO2, NO, NO2, H2, CL2, NH3, and H2S have a long service life of several years. The microprocessor NDIR detector for CO2, the RH sensor and the temperature sensor are all non-consumable. Specifications Method of Detection O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor, combustibles by catalytic sensor Ranges Available 0-100 PPM NO 0-100% RH 0-20 PPM H2S 0-20 PPM NH3 0-20.0 PPM CL2 0-20.0 PPM NO2 0-200 PPM CO 0-200 PPM H2 0-25.0% O2 0-50° C Temp. 0-50.0 PPM SO2 0-5000 PPM CO2 Resolution 0.1% on % gas, 1 PPM on PPM gas Accuracy & Repeatability ± 2% of full scale Drift Less than 1% of full scale or 1 PPM per 8 hours, whichever is greater, with constant ambient temperature Response Time ( T-90) Varies with individual sensor but generally under 2 minutes for full reading Ambient Temperature Range 4 to 49 º C - 40 to 120 º F Linearity ± 2% of full scale or 1 PPM, whichever is greater Size & Weight 15 " W x 7 " H x 12 " D @ 14 lbs. ( 375 x 175 x 305 mm @ 6.4 kg) Power 115 VAC, 60 Hz for recharging 220 VAC, 50 Hz Output Options 0-1 VDC - 4-20 mA Alarms Audible and visual alarms are optionally available as well as low battery and low flow Unique Applications Warm up time is approximately two minutes however NO and NH3 may take up to 2 hours for full stability. The operating humidity range for this series of analyzers is 0-90% RH non-condensing. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs. Primary Gas to be Measured Ammonia ( NH3) Carbon Dioxide ( CO2) Carbon Monoxide ( CO) Chlorine ( CL2) Hydrogen Fluoride ( HF) Hydrogen Sulfide ( H2S) Nitrogent Dioxide ( NO2) NO Oxygen ( O2) Sulfur Dioxide ( SO2) Models & Configuration Guidelines Standard system comes with ' K' series suitcase-style enclosure, built-in sampling pump, flow meter, pre-filter, liquid block, 12 ft ( 3.6 m) sample hose, rechargeable battery, and recharger. Arrange Gas numbers in the following order ( up to six gases) : 0) NH3 - 0-20 PPM 1) O2 - 0-25.0% 2) CO - 0-200 PPM 3) CO2 - 0-5000 PPM 4) LEL - Combustibles ( not avail. for 5287 Series) 5) H2S - 0-20 PPM 6) SO2 - 0-50 PPM 7) NO - 0-100 PPM 8) NO2 - 0-20 PPM 9) CL2 - 0-20 PPM Gases Measured 0) NH3 - 0-20 PPM 1) O2 - 0-25.0% 2) CO - 0-200 PPM 3) CO2 - 0-5000 PPM 4) LEL Combustibles ( not avail. for 5287 Series) 5) H2S - 0-20 PPM 6) SO2 - 0-50 PPM 7) NO - 0-100 PPM 8) NO2 - 0-20 PPM 9) CL2 - 0-20 PPM Industry Type Indoor Air Quality Personnel Safety Steel Making Applications For ambient air or confined space monitoring for up to any six choices of O2, CO2 SO2, NO, NO2, H2, CO, CL2, NH3, H2S, LEL combustibles, temperature, and % RH. Features Rugged design that is easy to operate and maintain Fast warm-up and response Separate electrochemical sensor for O2, CO, SO2, NO, NO2, H2, CL2, NH3, and H2S Sensitive infrared detector for CO2 Catalytic sensor for combustibles Capacitive ceramic sensor for % RH Digital readout with backlighting for each gas Built in sampling pump, flow meter, filter and 12 ft. sampling hose Rechargeable battery Rugged suitcase ( K) style case Options Recorder outputs of 0-1 V or 4-20 mA Audible and visual alarms Built in printer Detachable/ portable data logger Calibration Nitrogen ( N2) for zero Analyzed gas cylinders for span