  • Nova 600 Series Portable Single Gas Analyzer
Nova 600 Series Portable Single Gas Analyzer

Nova 600 Series Portable Single Gas Analyzer

Update Terakhir 28 / 03 / 2020
Minimal Pembelian 0 Unit

Harga

CALL
Bagikan
DESKRIPSI PRODUK

Detail Nova 600 Series Portable Single Gas Analyzer

APPLICATIONS For ambient air or confined space monitoring for a choice of any one of the following gases: H2S, SO2, Cl2, HCL & NH3. An optional O2 deficiency channel may also be added for a maximum of two gases. FEATURES • Rugged design that is easy to operate and maintain • Fast warm-up and response • Separate electrochemical sensor for each gas • Digital readout with backlighting for each gas • Built-in sampling pump, flow meter, filter and 12 ft. sampling hose • Rechargeable battery • Rugged suitcase ( K) style case DESCRIPTION The Nova 600 Series Portable Single-gas Ambient Air analyzers are convenient and accurate portable instruments for monitoring toxic gas in ambient air samples. A built-in pump draws in the sample gas where it is analyzed by the sensor. The detector output is then amplified and displayed on an easy-to-read digital meter. A choice of gases is available including H2S, SO2, Cl2, HCL, or NH3. An O2 sensor may be added to the single gas versions to produce a toxic gas plus oxygen deficiency monitor. The electrochemical sensors utilized in the 600 Series have a long service life of several years. SPECIFICATIONS Nova reserves the right to specification changes which may occur with advances in design without prior notice. UNIQUE APPLICATIONS Warmup time is approximately four minutes. The operating humidity range for this series of analyzers is 0-90% RH non-condensing. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. Description www.nova-gas.com Method of Detection: Ranges Available: Resolution: Accuracy and Repeatability: Drift: Response Time ( T-90) : Ambient Temperature Range: Linearity: Size and Weight: Power: Output Options: Alarms: O2, SO2, HCL, CL2, NH3 or H2S by electrochemical sensor 0-25.0% O2 0-20.0 PPM SO2 0-20 PPM HCL 0.1% on % O2, 1 PPM on PPM gases ± 2% of full scale Less than 1% of full scale or 2 PPM per 8 hours, whichever is greater, with constant ambient temperature Varies with individual sensor but generally under 2 minutes for full reading 40° to 120° F ( 4° to 49° C) Better than ± 2% of full scale 15" W x 7" H x 12" D @ 14 lbs. ( 375 x 175 x 305 mm @ 6.4 kg) 115VAC 60 Hz for recharging ( 220VAC 50 Hz also available) 4-20 mA or 0-1 VDC, built-in printer, detachable datalogger Low battery & low flow alarms are standard, audible & visual alarms per gas are optional