Automatic Cleveland Open Cup Flash Point Tester, Model : PT-SYD-3536A, Brand : Lab-Kits

Jumlah Pesanan: Tambah ke Keranjang
Negara Asal:Hong Kong SAR
Keterangan:Purpose
The instrument is designed and made as per the National Standard GB/ T3536, ISO 2592, ASTM 92 Test Methods for Flash Point and Fire Point of Petroleum Products ( Cleveland Open Cup Methods) , and T0651 Asphalt Flash Point and Fire Point Test ( Cleveland Open Cup Methods) in the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering. It is used to determine flash point of petroleum products and bituminous materials, excepting fuel oil and materials having a flash point of lower than 79 ° C.

Instrument features:
 Color LCD large screen display, full English interactive interface, no logo keyboard, Prompt menu guiding type input to the parameters as the pre-value of temperature, the sample label, atmospheric pressure and the date of the test;
 Simulation trace showing the curve of heating up and test time, with English software prompt modification function with the test date, the test time and other parameters prompts;
 Equipped with standard RS-323, 485 computer interface, lower computer storing 100 sets of historical data, can be connected to computer for mass storage data and can be stored for a long time, transmission of data, the host computer can modify the lower computer parameters.
 Automatic correction of the influence of atmospheric pressure on the test and calculate the correction value;
 Differential detection, system deviation automatic correction;
 Open the lid, ignition, detection, print data is done automatically. Electronic ignition, forced air cooling;
 Can detect ignition.

Technical parameters
Model PT-BWKS-8C
Measuring range Room temperature~ 400
Resolution 0.1
Repeatability d4
Reproducibility d± 6
Lift way Automatic tilt
Display mode Color screen
Detection mode Automatic
Data output Print
Ignition mode Electricity, gas
Experimental cup number Single cup
Operating environment 10-50
Relative humidity 85%
Power supply voltage AC220V
Power frequency 50Hz± 5%
Power rate d300W

Technical parameters
Model PT-BWKS-109
Measuring range Room temperature~ 450
Resolution 0.1
Repeatability d4
Reproducibility d± 6
Lift way Automatic tilt
Display mode Color screen
Detection mode Automatic
Data output Print
Ignition mode Electricity, gas
Experimental cup number Single cup
Operating environment 10-50
Relative humidity 85%
Power supply voltage AC220V
Power frequency 50Hz± 5%
Power rate d300W



Kontak Perusahaan
Nama:Tn. Supriatman [Pemasaran]
E-mail:
Situs Web:
Nomor Ponsel:Nomor ponsel Tn. Supriatman di Jakarta Timur
Nomor Telpon:Nomor telpon Tn. Supriatman di Jakarta Timur
Nomor Faks:Nomor faks Tn. Supriatman di Jakarta Timur
Alamat:Jl. Raya Kelapa Dua Wetan No. 42 Ciracas
Jakarta Timur 13730, Jakarta
Indonesia
menampilkan 148 dari 272 | Sebelum : PMCC Flash Point Tester, .... | Berikut : Cleveland Open Cup Flash....


Membuat situs langsung jadi?
Silahkan Klik disini!